Product description The MicroCal automated pressure transducer calibrator is used as a stand-alone calibration standard for differential and gauge pressure sensors found in critical environments. Setra partnered with NASA to develop the industry's quickest and most stable pressure control for low pressure range applications. Documentation and Software Download Center. Click here for current product Quick Start Guides, User Manuals, Configuration Guides, Specification Sheets, drivers, and more. Partners are encouraged to visit the Omron Microscan Partner Alliance Website for access to additional product materials. Omron Microscan Software Downloads. The MicroCal VP-ITC is a powerful and sensitive, easy-to-use isothermal titration calorimeter that offers the ability to investigate any biomolecular interaction. Its fast, convenient label-free in solution analysis delivers the information needed to characterize the molecular interactions of proteins, antibodies, nucleic acids and other.
Microcal Software 2017
GE Microcal VP-ITC
Summary Divx%2b codec.
The MicroCal VP-ITC (Isothermal Titration Calorimeter) unit directly measures heat evolved or absorbed in liquid samples as a result of mixing precise amounts of reactants. A spinning syringe is utilized for injecting and mixing of reactants. The user inputs the experimental parameters (temperature, number of injections, injection volumes) and the computer carries out the experiment. Origin® software is then used to analyze the ITC data using fitting models to calculate reaction stoichiometry (n), binding constant (KD), enthalpy (ΔH) and entropy (ΔS).
To avoid damage or contamination, researchers must provide their own Hamilton 81414 syringe for loading sample solutions. The syringe can be purchased through VWR via CyBuy or directly from Hamilton. The instrument must be reserved in advance, and various rules apply. Reserve time using iLab. Reservations do not require approval.
The instrument is located in 1238 Hach Hall. Enquiries should be directed to Sarah Cady. Phone 515-294-5975 (office). NOTE: The Microcal ITC is now serviced and supported by the Malvern company. The weblink is: http://www.malvern.com/en/products/measurement-type/microcalorimetry/default.aspx.
FY'18 Rates
The instrument is to be used by students and other researchers. Significant training is required, including sucessful completion of several tutorials and lessons before you will be authorized to use the instrument. Staff will NOT provide methods development assistance for this instrument, but will direct you to internet-based ITC resources. The hourly rates are listed below. NOTE: There is a minimum charge of $10 for each use of the instrument.
User Category | Instrument Charge | Staff Assistance |
---|---|---|
ISU researchers | $2.70 | $30 |
Non-ISU academic researchers | $4.05 | $45 |
Non-academic users | $8.10 | $90 |
Microcal VPITC Resources
Microcal Peaq-dsc Software
- Origin 7 Data Processing Lessons
- Lesson 1: Routine ITC Data Analysis and Fitting
- Lesson 2: Setting Baseline and Integration Range
- Lesson 3: Deleting Bad Data
- Lesson 4: Analyzing Multiple Runs and Subtracting Reference
- Lesson 5: ITC Data Handling
- Lesson 6: Modifying Templates
- Lesson 7: Advanced Curve Fitting
- Lesson 8: Autosampler Data (Optional Accessory)
- Lesson 9: Other Useful Details
- Appendix: Equations Used for Fitting ITC Data
- VPITC Users Manual (factory)
Malvern MicroCal PEAQ ITC Automated
MicroCal PEAQ ITC Automated offers the highest sensitivity with automation for high throughput, label free measurements of binding affinity and thermodynamics for the study of biomolecular interactions.
Malvern MicroCal PEAQ ITC Automated
MicroCal PEAQ ITC Automated offers the highest sensitivity with automation for high throughput, label free measurements of binding affinity and thermodynamics for the study of biomolecular interactions.
Manufacturer | Malvern Panalytical |
---|---|
Product Series | Malvern MicroCal ITC |
Measurement principle | Isothermal Titration Calorimetry |
Application | Biomolecular Interactions, Protein Interactions & Binding Affinity |
Sample type | Proteins, Biomolecules |
Sample Throughput | upto 42 per 24h (4x96 well plates) |
Noise | 0.15 ncal/s |
Temperature Range | 2℃ to 80℃ |
Response Time | 8s |
Product Overview
MicroCal PEAQ ITC Automated combines the high sensitivity of the MicroCal PEAQ ITC with walkaway automation to meet the productivity needs of busy research and drug discovery laboratories. Temperature controlled 4 x 96 well plates and user guided software together enable exceptional sensitivity and high quality data with robust operation. ITC is an essential tool in drug discovery and enables the study of biomolecular interactions as well as changes in conformation such as protein unfolding. It can also be used to measure enzyme kinetics.
Microcal Peaq-itc Analysis Software
MicroCal PEAQ ITC Automated measures heat released or absorbed during biochemical binding events to calculate binding affinity (K D ), stoichiometry (n), enthalpy (ΔH) and entropy (ΔS) in a single experiment. The system uses Isothermal Titration calorimetry (ITC), a technique that requires NO labelling and minimal assay development.
The PEAQ ITC micro calorimeter comprises two cells — a sample cell in which the titration experiment is performed, and a reference cell which contains only water. A series of small aliquots of ligand are injected into the sample or protein solution. If binding occurs between the ligand and protein, heat changes of a few millionths of a degree Celsius are detected and measured until the binding reaction has reached equilibrium. The quantity of heat measured is directly proportional to the amount of binding which helps the user understand the nature of the interaction. Vw radio code calculator download.
Benefits
All the benefits of the MicroCal PEAQ ITC plus:
Fully automated, high throughput
The MicroCal ITC Automated is a configurable, low volume, highly sensitive isothermal titration calorimeter. It offers the convenience of unattended operation with the capacity to run four 96 well plates simultaneously.
User-friendly software
Intuitive software ensures efficient experimental design with optimised automation scripts for robust operation with a variety of sample types and conditions. Design tools assist in selecting experimental run parameters to deliver fast, reliable results. New experiments can be edited ‘on the run’ to increase productivity.
Make Product EnquiryApplications
- Characterise biomolecular interactions to confirm binding, stoichiometry and thermodynamics
- Study the interaction between proteins, antibodies, nucleic acids, lipids, drugs and inhibitors
- Drug discovery for hit validation, lead optimisation and mechanisms of action Measure enzyme kinetics
Related products
Malvern MicroCal PEAQ ITC
MicroCal PEAQ ITC offers the highest sensitivity for label free measurements of binding affinity and thermodynamics with low sample consumption for the study of biomolecular interactions.
Find out moreMalvern MicroCal PEAQ-DSC
![Software Software](https://malvern.ssl.cdn.sdlmedia.com/636216790330132101MU.jpg)
MicroCal PEAQ-DSC is a highly sensitive, easy-to-use Differential Scanning Calorimeter (DSC) that provides insights into biomolecular stability without labelling or use of artificial probes.
Microcal Software Pdf
Find out moreMicrocal Software Reviews
Malvern MicroCal PEAQ-DSC Automated
Microcal Originpro Software
MicroCal PEAQ-DSC Automated is a highly sensitive, fully automated Differential Scanning Calorimeter (DSC) that provides insights into biomolecular stability without labelling or use of artificial probes.
Find out moreProduct Enquiry
To enquire about this product, please send through your details below and one of our product specialists will be in touch to discuss your requirements.